Select Projects
Perelman Center for Performing Arts at the World Trade Center
New York, New York
Groundborne / Structureborne vibration assessment and building vibration isolation design for a new arts center with 199-, 299-, and 550-seat theaters.
Jazz at Lincoln Center
New York
Measurement and evaluation of groundborne vibration and noise from NYCT subway trains. Building isolation design for Rose Theater to achieve the threshold of hearing.
Suzanne Roberts Theater
Philadelphia
Building isolation design for the performance hall of a small theater incorporated into a larger building, located adjacent to the SEPTA Broad Street subway line.
Kimmel Center
Philadelphia
Groundborne vibration study/building isolation design for the Philadelphia Orchestra performance hall and Perelman Theater located adjacent to the SEPTA Broad Street rail subway.
Benaroya Concert Hall
Seattle
Measurement and evaluation of groundborne vibration and noise from trains operating in tunnel below site. Mitigation feasibility assessment and design of hall vibration and noise isolation.
Four Seasons Centre for Performing Arts
Toronto
Vibration analysis and control services for opera house located adjacent to subway and streetcar rail transit lines. Work included site vibration survey and building isolation design.
Sangnam Hall
Seoul, Korea
Groundborne noise and vibration study and building isolation design for performance hall above parking, adjacent to an office building tower and adjacent to a rail transit subway line.
Roy and Edna Disney/CalArts Theater (REDCAT)
Los Angeles
Building vibration isolation design including structural acoustic bearings for theater building.
Singapore Performing Arts Center: Esplanade Theaters on the Bay
Singapore
Groundborne vibration study and building isolation design for project adjacent to four subway tunnels. Isolation design for glass roof structure and lobby canopies.
Bartók National Concert Hall
Budapest
Review of vibration levels from nearby railroad operations and building isolation design for new concert hall.
Six Continents Hotel
500 Atlantic Avenue, Boston
Isolation design for hotel/condominium building located directly on top of roadway tunnel ventilation building that had large supply and exhaust fans creating high levels of structure-borne noise.
Theatre for a New Audience
Brooklyn, New York
Site groundborne noise and vibration study and measurements; development of the structural isolation design using natural rubber isolation bearings.
Contact Us About Your Project
Successful isolation on projects where potential sources of groundborne or structure-borne noise and vibration impacts.
Evaluate existing groundborne vibration and noise
Project expected vibration and noise
Determine isolation design requirements
Develop effective isolation designs
Provide detailed design, materials and specifications for isolation systems